Products / UL Listed Sprinkler
 
 
Horizontal Sidewall Sprinkler

Response: Standard or Quick
Coverage: Water discharge is directed primarily outward and downward in a quarter spherical pattern, a portion of the spray is also directed towards the back wall.
Installation: Designed for installation along a wall or the side of a beam just beneath a smooth ceiling. Installed 4 to 12 in. below ceiling. (Ref. NFPA 13)
Orifice Size: 1/2'' (15mm)
Thread Size: NPT1/2''or R1/2''(ISOT/1)
Temp. Rating: 57, 68, 79, 93 degrees centigrade.
Maximum Service Pressure: 175 psig / 1. 2Mpa (12 bar)
Listing and Approvals: UL / ULC / CCC (China)
Finishes: Natural Brass, Chrome Plated.

View Details
Technical Data Sheet – TD2001R-1.pdf

Upright Sprinkler
Response: Standard or Quick
Coverage: Produce a hemispherical water distribution pattern below the deflector.
Installation: Upright installed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency(Ref. NFPA 13).
Orifice Size: 1/2'' (15mm)
Thread Size: NPT1/2''or R1/2''(ISOT/1)
Temp. Rating: 57, 68, 79, 93 degrees centigrade.
Maximum Service Pressure: 175 psig / 1. 2Mpa (12 bar)
Listing and Approvals: UL / ULC / FM/ CCC (China)
Finishes: Natural Brass, Chrome Plated.
View Details
Technical Data Sheet – TD2002R-1.pdf

Pendent Sprinkler
Response: Standard or Quick
Coverage: Produce a hemispherical water distribution pattern below the deflector.
Installation: Pendent installed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency(Ref. NFPA 13).
Orifice Size: 1/2'' (15mm)
Thread Size: NPT1/2''or R1/2''(ISOT/1)
Temp. Rating: 57, 68, 79, 93 degrees centigrade.
Maximum Service Pressure: 175 psig / 1. 2Mpa (12 bar)
Listing and Approvals: UL / ULC / CCC (China)
Finishes: Natural Brass, Chrome Plated.
View Details
Technical Data Sheet – TD2002R-1.pdf

Concealed General Description


Response: Standard or Quick
Coverage:
The concealed Pendent Sprinklers all produce a hemispherical water distribution pattern below the deflector. For coverage area and sprinkler placement, refer to NFPA 13 standards.
Installation:
Concealed installation in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (Ref. NFPA13)
Orifice Size:
1/2” (15mm)
Thread Size:
NPT1/2” or R1/2” (ISO7/1)
Temp. Rating:
57, 68, 79, 93 degrees centigrade.
Maximum Service Pressure:
175 psig / 1. 2Mpa (12 bar)
Listing and Approvals:
UL / ULC /CCC (China)
Finishes:
Sprinkler – Natural Brass, Chrome Plated
Cover Plate – Any color, Chrome Plated
View Details
Technical Data Sheet – TD2003R.pdf
 